Windows and Doors Supply & Install

CALL: (416)843-4515
FAX: (416) 546-8663
Email: info@albvision.ca


homestars logoPost a review about us on homestars.ca!

sale

SPECIALIZING IN:

  • Installation
  • Replacement
  • Retrofitting
  • Vinyl Windows
  • Storm Doors
  • Sliding Vinyl Patio
  • Doors
  • Thermo Windows and Doors
  • Energy
  • Efficient/Saver windows and doors
CALL NOW and get
20% OFF!
(416)843-4515
>Click here<
Submit a free quote now!

Albvision windows and doors, long term supply and installation company. For over 20 years we've been installing and upgrading homes all over the GTA and beyond.

Albvision Windows and Doors qualify for the important ENERGY STAR rating by the federal government. We are pleased to be able to offer our customers the most energy efficient products on the market.

Albvision is a fully insured operating company.

Energy-efficient products will:






ENERGY STAR Performance Levels


ENERGY STAR qualified windows, doors and skylights are tested and certified by an independent, accredited agency. Products qualify for ENERGY STAR based on either their U-value or their Energy Rating. As well, windows and patio doors must achieve at least an A2 rating for airtightness. The tables below show the required ratings for windows, doors and skylights to be ENERGY STAR qualified for each climate zone in Canada.


ENERGY STAR Requirements for Windows and Doors Effective October 1, 2010
(Products may comply based on either their U-value and R-value or their Energy Rating)


Windows
Zone Heating
Degree-Day
Range
Compliance Paths
Energy Rating (ER) or U-Factor
Minimum ER (unitless)
Maximum U-Factor 2.00
W/m²•K
(0.35 Btu/h•ft.²•°F)
  Maximum
U-Factor
W/m²•K
(Btu/h•ft.²•°F)
Minimum
ER
(unitless)
A <= 3500 21 or 1.80 (0.32) 13
B > 3500 to <= 5500 25 or 1.60 (0.28) 17
C > 5500 to <= 8000 29 or 1.40 (0.25) 21
D > 8000 34 or 1.20 (0.21) 25

Doors
Zone Heating
Degree-Day
Range
Compliance Paths
Energy Rating (ER) or U-Factor
Minimum ER (unitless)
Maximum U-Factor 2.00
W/m²•K
(0.35 Btu/h•ft.²•°F)
  Maximum
U-Factor
W/m²•K
(Btu/h•ft.²•°F)
Minimum
ER
(unitless)
A <= 3500 21 or 1.80 (0.32) N/A
B > 3500 to <= 5500 25 or 1.60 (0.28) N/A
C > 5500 to <= 8000 29 or 1.40 (0.25) N/A
D > 8000 34 or 1.20 (0.21) N/A

ENERGY STAR Requirements for Skylights Effective October 1, 2010

Skylights* (Effective October 1, 2010)
Zone Heating Degree-Day Range Maximum U-Factor
W/m²•K (Btu/h•ft.²•°F)
A <= 3500 2.80 (0.50)
B > 3500 to <= 5500 2.60 (0.46)
C > 5500 to <= 8000 2.40 (0.42)
D > 8000 2.20 (0.39)
*includes Tubular Skylights